• Facebook
  • Twitter
  • Instagram
  • LinkedIn
  • Mail
Ph: +91 9711 774744. eMail: info@suvastika.com
Su-vastika
  • Home
  • About Us
    • Our Story
    • Research and Development
    • Patents
      • Technology Patents
      • Design Patents
    • FAQ
      • UPS & Inverter FAQs
      • Technology FAQs
      • Electricity FAQs
      • Battery FAQs
    • Certificates
      • BIS Certificate
      • Copyrights
      • Electrical Contractor License
      • Export House Certificate
      • GST Certificate
      • IEC Certificate
      • ISO 9001 CERTIFICATE
      • Indian Custom Certificate
      • Licensed Product Certificate
      • Startup Certificate
      • MSME Certificate
      • UN Certificate
  • News
  • Products
    • Battery Backup & Power Storage Solutions
      • Home & Commercial UPS
        • Economical Range
        • Premium Range with ATC
      • WI-FI Based UPS
      • Heavy Duty UPS (IGBT Based Technology)
        • Single Phase (6.5KVA-15KVA)
          • Heavy Duty UPS 6.5KVA
          • Heavy Duty UPS 7.5KVA
          • Heavy Duty UPS 10 KVA
          • Heavy Duty UPS 15KVA
        • Three Phase (10KVA-500KVA)
          • Heavy Duty UPS 10KVA (3P-3P)
          • Heavy Duty UPS 15KVA (3P-3P)
          • Heavy Duty UPS 20KVA (3P-3P)
          • Heavy Duty UPS 30KVA (3P-3P)
          • Heavy Duty UPS 40KVA (3P-3P)
          • Heavy Duty UPS 50KVA (3P-3P)
          • Heavy Duty UPS 80KVA (3P-3P)
          • Heavy Duty UPS 100KVA (3P-3P)
          • Heavy Duty UPS 200KVA (3P-3P)
          • Heavy Duty UPS 250KVA (3P-3P)
          • Heavy Duty UPS 500KVA (3P-3P)
    • Solar
      • Solar Panels
      • Solar PCU/OFF Grid Solar System/Solar Hybrid UPS
        • Home and Comemrcial UPS (Mosfet based)
          • Economical(PWM Based) 850VA-1600VA
            • Solar Hybrid PCU 1100VA
            • Solar Hybrid PCU 1600VA
          • Premium (MPPT Based) 1250VA-5500VA
            • Solar Hybrid PCU 1500VA
            • Solar Hybrid PCU 2500VA
            • Solar Hybrid PCU 3500VA
            • Solar Hybrid PCU 5500VA
      • WIFI Based UPS (1250VA-5500VA)
      • Heavy Duty (IGBT Based)
        • 3P-3P MPPT (10KVA-100KVA)
    • Energy Storage System (ESS)
      • 1 Phase 6.5 KVA – 15 KVA
      • 3 Phase 10 KVA – 500 KVA
    • Lift/Escalators Backup
    • Battery
      • Lithium Battery (LiFePO4)
    • Online UPS (With Galvanic Isolation)
      • 1P-1P IGBT Based (5KVA-10KVA)
        • Online UPS 5KVA/180V
        • Online UPS 10KVA/180V
      • 3P-3P IGBT Based(10KVA-30KVA)
        • Heavy Duty online UPS 10KVA/360V
        • Heavy Duty online UPS 15KVA/360V
        • Heavy Duty online UPS 20KVA/360V
        • Heavy Duty online UPS 30KVA/360V
      • Solar Based Online UPS
    • EV Chargers
      • For Scooter/Motorcycle
      • For Cars
    • Automatic Testing Setup (ATS)
      • PCB Testing Machines
      • Transformer Testing Machines
      • Inverter/UPS/Solar testing machines
      • Electric Vehicle Testing Machines
      • Lithium Battery testing Machines
    • Export
  • Contact
  • Blog
  • Menu Menu

Load Combinations run by our UPS

*All loads combination were checked and tested in ideal conditions.

What does UPS do?

Key Features

SMART AVR

SAFE VOLTAGE RANGE

ADVANCED PROTECTION

AUTOMATIC BYPASS

PURE SINE WAVE

ADAPTIVE PERFORMANCE

SAFE CHARGING

BACKUP SELECTIOn

POWER RESERVE

LOW REQUISITE

SOFT START

GENERATOR COMPATIBLE

Works in three modes

When Grid supply is available

Smart AVR

(Automatic Voltage Regulation)

Frequent voltage and frequency fluctuations in households are common occurrences. The moment voltage supply goes down below a certain level, we observe the speed of fans going slow, the blub light dimming, or the tube light blinking frequently. This is called a Low Voltage supply. Also, there are occasions when the voltage jumps high. We all may have observed that as we switch the bulb on, it goes off and gets fused as it cannot withstand a High Voltage spike.

Safe Voltage Range (Brain with a Muscle) Suppose there is a sudden high voltage spike. Now your home’s MCB might not be able to protect your appliances, but your Fusion eco will. It will rapidly switch from the mains to the battery. In fact, Fusion eco can take up to 2.5x its load capacity, supporting your entire load during that high voltage spike. It then intelligently reminds you to turn off the extra appliances, so that the load can be reduced.

With Smart Automatic Voltage Regulation (AVR) feature or when your mains supply voltage fluctuates (rises or drops beyond the Safe Voltage range), Fusion eco seamlessly switches to the battery power, ensuring a safe power supply to all your appliances.

Safe Voltage Range

(Brain with a Muscle)

Suppose there is a sudden high voltage spike. Now your home’s MCB might not be able to protect your appliances, but your Fusion eco will. It will rapidly switch from the mains to the battery. In fact, Fusion eco can take up to 2.5x its load capacity, supporting your entire load during that high voltage spike. It then intelligently reminds you to turn off the extra appliances, so that the load can be reduced.

Advanced Protection

Short circuits are very common. Therefore every household is equipped with an MCB or main fuse. However, these can be slow and inefficient at protecting your appliances from damage.

We know how much you love your appliances. Therefore, we have designed Fusion eco to add a smart layer of protection to them. It has an inbuilt Special MCB, which trips and protects all your appliances even before the traditional MCB can respond.

Charging Section

There are multiple type of Batteries available in the market which has the advantages and disadvantages and accordingly we charge them based on their characteristics. For example if we have to charge a Tubular Lead Acid battery than we have to take the minimum time of 10 hours before we completely charge it. If we try to charge faster than these Batteries will be short lived and need frequent water topping.

If we have to charge the Valve Regulated Lead Acid Batteries which are called sealed Maintenance Free batteries they need to be charged in 6 to 8 hours and if we try to charge them faster than that their life is also reduced. In case of Lithium Batteries we can charge them in 2 to 4 hours and they have a life cycle nearly 5 times than that of Lead Acid Batteries. It’s very important how the charger of a UPS is designed to take care of the battery as the life of the battery will majorly dependent on the charger technology.

Our UPS has the charging capacity of 15 Amp which can charge the 150 Ah battery in 10 hours .So the size of the charger is very important to check before buying any UPS. The next parameter is how the charging is done is it flat charging or it’s done in stages. In Lead Acid battery charging has to be fast till the 80 percent of the charge but rest 20 percent need little slow charging because the water is hot inside the battery when we are charging it so we need to follow a pattern by which we reduce the heating when we are charging it so that water doesn’t evaporate and the more we control the heating inside the battery life of the battery is increased.

 

Battery Charging Mechanism

Fusion Eco is built with a Right Charging Mechanism that charges batteries optimally for longer life

Safe Charging (Six stage charging)

Most inverters charge the battery in a flat, linear manner. But just like monotony upsets you, monotonous or flat charging deteriorates battery health.

Ideally, 80% of a battery should be fast-charged, while the rest 20% should be charged slowly to avoid overheating and loss of water-topping. With its Generation Four microprocessor, Falcon Plus carries out charging in six thoughtful stages for maximum efficiency in charging.

 

Adaptive Performance Using ATC

Falcon Plus is designed for rough weather conditions. It has an ambient sensor and antenna placed right upon it. With advanced Automatic Temperature Compensation (ATC) built right into the microprocessor, Falcon Plus senses the temperature around it and then makes intelligent adjustments. For example, in summers or hotter regions, the temperature is high, and hence the battery is charged to a lower voltage for the same power back-up performance. This saves you some extra bucks while also making sure the battery doesn’t overheat, lose water, or get damaged. Similarly, in winters or colder places, the temperature is lower and hence the battery is charged to a higher boost voltage to make sure you get the required or expected amount of power backup. This makes Falcon Plus a perfect choice for any climate, from the extremes of Northern America and Europe to the beating heat in Middle-East and South-East Asia, we are ready for a rough world

Low Requisite

Typically, batteries require a 130V input to charge itself, but this is not available across the world at every time.
Regions with frequent outages and low grid voltages may result in poor or no charging.
In such cases, people resort to using stabilizers to get optimum voltage for charging. To ease this, Fo is equipped with Advanced Circuitry that charges the battery with as low as 90V input.

Automatic Bypass

Now, what if your UPS has a technical error, and is unable to switch your load back to the main supply? And imagine this happens in the middle
of a summer night, and an electrician can only come the next morning. Intolerable, right?

This is common with almost every UPS or Inverter but not in the Falcon plus models because it has a feature of ‘Automatic bypass system’ which bypasses the Mains supply even when the UPS is faulty.

 

Intelligently changing between mains and backup

Fast Switching

Traditional inverters have higher switching time. This means your appliances will reset during changeover
between mains to backup.

Falcon plus is blazingly fast. It automatically detects a power-cut or voltage fluctuation and switches to its
backup mode in milliseconds. So you and your appliances won’t even get to know there was a power-cut.

This means your computer, Wi-Fi, and other critical equipment can run uninterrupted without resetting.

Because who likes to stop?

Pure Sine Wave Technology

Many inverters still provide a square wave output which is not healthy for your appliances. Falcon Plus is designed to provide a smooth, continuous pure sinewave power output to your appliances just as they require it.

Backup Selection Feature

Every battery is built to accept a certain maximum allowed charging speed. A Tubular Lead-Acid battery needs a minimum of 10 hours, a Sealed Maintenance Free (SMF) battery requires 6-8 hours, while a
Lithium-Ion battery requires 2-4 hours to get fully charged in a healthy way.

Charging the batteries faster than these healthy limits reduces the battery’s life, and increases maintenance costs and hassles. That’s why Falcon Plus is built with the Right Charger that charges batteries at optimum speed

Battery Selection Switch is an innovative feature of Falcon Plus that enables you to select the battery type you have installed so that it can control and optimize the charging speed to keep your battery healthy. This makes Falcon Plus compatible with diverse battery sizes as per user need for load and backup time.

Different Battery Capacity selection feature.
It is a very smart feature packed in to this UPS as it helps the customer to select the different sizes of battery according to their backup needs.

As the times are changing the power condition in different geographies is changing over a period of time so let us take an example that today in a city like Gurgaon, power cuts are very common and each power cut has two hour of black out so the customer will buy a battery which will provide two hour back up.

But after two years this power cut is reduced to 15 min then customer requirement has changed now and customer needs a battery which will provide only 15 min of back up but in actually customer will not be able to take a smaller battery as the UPS is designed for a 2 hour back up battery as normal UPS/Inverters available in the industry are of 15A fixed charger where a battery of 150-200 Ah is must. If a customer want to use a smaller battery in the very same UPS then that battery will be swelled over a period of time because the current is too high for a smaller battery to handle.

Keeping this problem in mind we have designed a different type of chargers in a single UPS using the AI technology and the selection of smaller to bigger battery can be selected by using DIP switch provided at the back panel.

So the customer has a future assurance provided that whenever they had to change the battery they can select the smaller to bigger battery as per the power situation in their region. This feature gives customer a big advantage compare to fix type of battery charging technology and most importantly saving your precious money.

Discharging Mechanism:

Letting out energy to your appliances elegantly is a breeze for Fusion Eco. We focus on keeping both your appliances & the battery fine.

Safe Discharge with LVC Feature

With prolonged usage, a battery’s life gets reduced. This is what happens to every battery after multiple charge-discharge cycles, even inverter batteries. Nerds call it battery fatigue.

Falcon Plus knows how to beat this problem too. When the battery is being used to power your appliances and is about to get empty (but not fully empty), Falcon Plus places a reserve. This means it doesn’t let the battery get fully or deeply discharged, hence extending the life of the battery by leaps and bounds.

This is similar to the reserve tank we have in our cars and scooters. It makes sure that even after you run out of battery power, you are still left with the reserved capacity to get done with emergency situations, by simply pressing a button.

A battery’s L:ow voltage cut-off (LVC) is the voltaghe level at which the charger disconncts the load from the battery. It is when the battery stops pwoering your fans, refrigerators and other loads in the house. the function of the cut-off voltage is to prevent the battery from enetering the deep discharge stage.

Soft Start

(Gentle to your appliances)

A great beginning makes way for a great journey. Fusion eco knows this very well.
Unlike traditional inverters that allow a sudden inrush of current which can be harmful to your appliances, Fusion eco goes for a cushioned start-up.
It gradually increases the voltage to let your appliances ease-in. This prevents electrical and mechanical shocks to the sensitive and costly appliances in your house.

Generator Compatible

Many times when the local grid fails, you need to depend on your Domestic Power Generators.
Ordinary inverters are incompatible with such ACs due to their high fluctuations. But Fusion eco can normalize and adapt to such fluctuations, making it perfect to pair up with Domestic Generators because our UPS has a frequency bypass range of 42Hz – 55Hz.

Overload & Short circuit Feature

We have given a special overload feature in which when the ups once get overloaded will give 8 times retry before it shuts down. This feature is very important for the customer as when the costumer put extra load which cannot be supported by the ups then it switch off immediately and keep giving warning.

Then customer has to reduce the load and go to the ups and reset the front switch which is very uncomfortable for the costumer because at times the whole house gets into darkness and for the costumer to switch off the load and reaches to the ups is tough as it laying in one corner of the house or office.

So we have given a special feature in our ups, in case of overload our ups gives you 8 times switching on and off load, in that timing costumer can reduce the load and there is no sudden darkness in the house/office.

Just like overload retries our UPS has a feature of short circuit retries as well. In this feature whenever there is a short circuit our UPS will shut down automatically and start again. In this process our UPS will check whether the condition of short circuit has been eliminated or not if the short circuit has been eliminated the UPS will start working normally and if condition of short circuit continues then our UPS will retry 4 times before permanently shut down. In order to make it operational again, reset the front switch of UPS. 

Isolation Transformer

Our UPS have Built-in Isolation Transformer. Isolation also referred to as galvanic isolation, implies that no direct path exists for the current
to flow from the source to the load. An isolation transformer provides isolation between the electrical devices and the source powering these devices. In other words, with an isolation transformer, the output power circuit is electrically and physically isolated from the input power circuit. As a result, the isolation transformer provides safety to the users and the appliances.

Bi-Directional Technology

Su-vastika’s UPS works on the Revolutionary Bi-directional technology. A bi-directional technology is a technology that allows for two-way charging due to its ability of two-way conversion—from AC to DC and from DC to AC.

A bi-directional technology uses the same PWM (Pulse Width Modulation) based, MOSFET (metal–oxide–semiconductor field-effect transistor) circuit to charge and discharge the battery.

LCD Display Message

1350VA

So now you know why we say Falcon Plus is the smartest thing we’ve ever made. Well, it’s just because when we set out to make a product, we don’t aim for beating our competition, we instead aim to push humanity forward.

Technical Specification

*SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT ANY PRIOR NOTICE

MODEL(FUSION ECO)

2300A

BATTERY VOLTAGE

24V

TECHNOLOGY

LATEST BI-DIRECTIONAL TECHNOLOGY

MAINS MODE
INPUT VOLTAGE RANGE (WUPS MODE)

85V-290V

INPUT VOLTAGE RANGE (UPS MODE)

185V-265V

OUTPUT VOLTAGE

SAME AS INPUT

CHARGING CURRENT

 15A, 20A (USER SELECTABLE)

FREQUENCY BYPASS RANGE

42Hz- 55Hz

CHANGE OVER TIME
UPS MODE

≤ 8 ms

WUPS MODE

≤ 20 ms

BATTERY MODE
OUTPUT WAVEFORM

PURE SINE WAVE

OUTPUT FREQUENCY

50.0 ± 0.1Hz

TOTAL HARMONIC DISTORTION (THD)

<3%

PROTECTIONS
MAINS MODE:
OVERLOAD/SHORT CIRCUIT

MAINS MCB WILL TRIP

BATTERY OVERCHARGE

BATTERY HIGH CUT

BATTERY MODE:
OVERLOAD PROTECTION

YES WITH 8 TIMES AUTO RESET

SHORT CIRCUIT PROTECTION

YES WITH 4 TIMES AUTO RESET

OVER TEMPERATURE PROTECTION

YES HIGH TEMPERATURE SHUTDOWN

AUTOMATIC TEMPERATURE COMPENSATION (ATC)

-10°C to 60°C

OPERATING TEMPERATURE

-10°C to 45°C

Related

Head Office

206, 2nd Floor,JMD Regent Plaza, MG Road, Sikanderpur, Sector 26. Gurugram Pin-122002

Latest News

  • How IoT is going to revolutionize the Inverter/UPS, and Home UPS marketHow IoT is going to revolutionize the Inverter/UPS, and Home UPS marketJanuary 29, 2023 - 1:01 am
  • All in One Technology that brings the benefits of Inverter UPS and off grid UPS togetherJanuary 24, 2023 - 2:25 pm
  • The Lithium Battery Technology is going to change the Battery Storage SolutionsThe Lithium Battery Technology is going to change the Battery Storage SolutionsJanuary 24, 2023 - 2:20 pm

Contact

Email : info@suvastika.com
Toll-free : 1800-202-4423
Sales : +91 9711 774744
© Copyright - Su-vastika Systems Private Limited. - powered by Enfold WordPress Theme
  • Facebook
  • Twitter
  • Instagram
  • LinkedIn
  • Mail
  • Home
  • About Us
  • News
  • Products
  • Contact
  • Blog
Scroll to top