Load Combinations run by our UPS
*All loads combination were checked and tested in ideal conditions.
What does UPS do?
Key Features
SMART AVR
SAFE VOLTAGE RANGE
ADVANCED PROTECTION
AUTOMATIC BYPASS
PURE SINE WAVE
ADAPTIVE PERFORMANCE
SAFE CHARGING
BACKUP SELECTIOn
POWER RESERVE
LOW REQUISITE
SOFT START
GENERATOR COMPATIBLE
Works in three modes
When Grid supply is available
Smart AVR
(Automatic Voltage Regulation)
Frequent voltage and frequency fluctuations in households are common occurrences. The moment voltage supply goes down below a certain level, we observe the speed of fans going slow, the blub light dimming, or the tube light blinking frequently. This is called a Low Voltage supply. Also, there are occasions when the voltage jumps high. We all may have observed that as we switch the bulb on, it goes off and gets fused as it cannot withstand a High Voltage spike.
Safe Voltage Range (Brain with a Muscle) Suppose there is a sudden high voltage spike. Now your home’s MCB might not be able to protect your appliances, but your Fusion eco will. It will rapidly switch from the mains to the battery. In fact, Fusion eco can take up to 2.5x its load capacity, supporting your entire load during that high voltage spike. It then intelligently reminds you to turn off the extra appliances, so that the load can be reduced.
With Smart Automatic Voltage Regulation (AVR) feature or when your mains supply voltage fluctuates (rises or drops beyond the Safe Voltage range), Fusion eco seamlessly switches to the battery power, ensuring a safe power supply to all your appliances.
Safe Voltage Range
(Brain with a Muscle)
Suppose there is a sudden high voltage spike. Now your home’s MCB might not be able to protect your appliances, but your Fusion eco will. It will rapidly switch from the mains to the battery. In fact, Fusion eco can take up to 2.5x its load capacity, supporting your entire load during that high voltage spike. It then intelligently reminds you to turn off the extra appliances, so that the load can be reduced.
Advanced Protection
Short circuits are very common. Therefore every household is equipped with an MCB or main fuse. However, these can be slow and inefficient at protecting your appliances from damage.
We know how much you love your appliances. Therefore, we have designed Fusion eco to add a smart layer of protection to them. It has an inbuilt Special MCB, which trips and protects all your appliances even before the traditional MCB can respond.
Charging Section
There are multiple type of Batteries available in the market which has the advantages and disadvantages and accordingly we charge them based on their characteristics. For example if we have to charge a Tubular Lead Acid battery than we have to take the minimum time of 10 hours before we completely charge it. If we try to charge faster than these Batteries will be short lived and need frequent water topping.
If we have to charge the Valve Regulated Lead Acid Batteries which are called sealed Maintenance Free batteries they need to be charged in 6 to 8 hours and if we try to charge them faster than that their life is also reduced. In case of Lithium Batteries we can charge them in 2 to 4 hours and they have a life cycle nearly 5 times than that of Lead Acid Batteries. It’s very important how the charger of a UPS is designed to take care of the battery as the life of the battery will majorly dependent on the charger technology.
Our UPS has the charging capacity of 15 Amp which can charge the 150 Ah battery in 10 hours .So the size of the charger is very important to check before buying any UPS. The next parameter is how the charging is done is it flat charging or it’s done in stages. In Lead Acid battery charging has to be fast till the 80 percent of the charge but rest 20 percent need little slow charging because the water is hot inside the battery when we are charging it so we need to follow a pattern by which we reduce the heating when we are charging it so that water doesn’t evaporate and the more we control the heating inside the battery life of the battery is increased.
Battery Charging Mechanism
Fusion Eco is built with a Right Charging Mechanism that charges batteries optimally for longer life
Safe Charging (Six stage charging)
Most inverters charge the battery in a flat, linear manner. But just like monotony upsets you, monotonous or flat charging deteriorates battery health.
Ideally, 80% of a battery should be fast-charged, while the rest 20% should be charged slowly to avoid overheating and loss of water-topping. With its Generation Four microprocessor, Falcon Plus carries out charging in six thoughtful stages for maximum efficiency in charging.
Adaptive Performance Using ATC
Falcon Plus is designed for rough weather conditions. It has an ambient sensor and antenna placed right upon it. With advanced Automatic Temperature Compensation (ATC) built right into the microprocessor, Falcon Plus senses the temperature around it and then makes intelligent adjustments. For example, in summers or hotter regions, the temperature is high, and hence the battery is charged to a lower voltage for the same power back-up performance. This saves you some extra bucks while also making sure the battery doesn’t overheat, lose water, or get damaged. Similarly, in winters or colder places, the temperature is lower and hence the battery is charged to a higher boost voltage to make sure you get the required or expected amount of power backup. This makes Falcon Plus a perfect choice for any climate, from the extremes of Northern America and Europe to the beating heat in Middle-East and South-East Asia, we are ready for a rough world
Low Requisite
Typically, batteries require a 130V input to charge itself, but this is not available across the world at every time.
Regions with frequent outages and low grid voltages may result in poor or no charging.
In such cases, people resort to using stabilizers to get optimum voltage for charging. To ease this, Fo is equipped with Advanced Circuitry that charges the battery with as low as 90V input.
Automatic Bypass
Now, what if your UPS has a technical error, and is unable to switch your load back to the main supply? And imagine this happens in the middle
of a summer night, and an electrician can only come the next morning. Intolerable, right?
This is common with almost every UPS or Inverter but not in the Falcon plus models because it has a feature of ‘Automatic bypass system’ which bypasses the Mains supply even when the UPS is faulty.
Intelligently changing between mains and backup
Fast Switching
Traditional inverters have higher switching time. This means your appliances will reset during changeover
between mains to backup.
Falcon plus is blazingly fast. It automatically detects a power-cut or voltage fluctuation and switches to its
backup mode in milliseconds. So you and your appliances won’t even get to know there was a power-cut.
This means your computer, Wi-Fi, and other critical equipment can run uninterrupted without resetting.
Because who likes to stop?
Pure Sine Wave Technology
Many inverters still provide a square wave output which is not healthy for your appliances. Falcon Plus is designed to provide a smooth, continuous pure sinewave power output to your appliances just as they require it.
Backup Selection Feature
Every battery is built to accept a certain maximum allowed charging speed. A Tubular Lead-Acid battery needs a minimum of 10 hours, a Sealed Maintenance Free (SMF) battery requires 6-8 hours, while a
Lithium-Ion battery requires 2-4 hours to get fully charged in a healthy way.
Charging the batteries faster than these healthy limits reduces the battery’s life, and increases maintenance costs and hassles. That’s why Falcon Plus is built with the Right Charger that charges batteries at optimum speed
Battery Selection Switch is an innovative feature of Falcon Plus that enables you to select the battery type you have installed so that it can control and optimize the charging speed to keep your battery healthy. This makes Falcon Plus compatible with diverse battery sizes as per user need for load and backup time.
Different Battery Capacity selection feature.
It is a very smart feature packed in to this UPS as it helps the customer to select the different sizes of battery according to their backup needs.
As the times are changing the power condition in different geographies is changing over a period of time so let us take an example that today in a city like Gurgaon, power cuts are very common and each power cut has two hour of black out so the customer will buy a battery which will provide two hour back up.
But after two years this power cut is reduced to 15 min then customer requirement has changed now and customer needs a battery which will provide only 15 min of back up but in actually customer will not be able to take a smaller battery as the UPS is designed for a 2 hour back up battery as normal UPS/Inverters available in the industry are of 15A fixed charger where a battery of 150-200 Ah is must. If a customer want to use a smaller battery in the very same UPS then that battery will be swelled over a period of time because the current is too high for a smaller battery to handle.
Keeping this problem in mind we have designed a different type of chargers in a single UPS using the AI technology and the selection of smaller to bigger battery can be selected by using DIP switch provided at the back panel.
So the customer has a future assurance provided that whenever they had to change the battery they can select the smaller to bigger battery as per the power situation in their region. This feature gives customer a big advantage compare to fix type of battery charging technology and most importantly saving your precious money.
Discharging Mechanism:
Letting out energy to your appliances elegantly is a breeze for Fusion Eco. We focus on keeping both your appliances & the battery fine.
Safe Discharge with LVC Feature
With prolonged usage, a battery’s life gets reduced. This is what happens to every battery after multiple charge-discharge cycles, even inverter batteries. Nerds call it battery fatigue.
Falcon Plus knows how to beat this problem too. When the battery is being used to power your appliances and is about to get empty (but not fully empty), Falcon Plus places a reserve. This means it doesn’t let the battery get fully or deeply discharged, hence extending the life of the battery by leaps and bounds.
This is similar to the reserve tank we have in our cars and scooters. It makes sure that even after you run out of battery power, you are still left with the reserved capacity to get done with emergency situations, by simply pressing a button.
A battery’s L:ow voltage cut-off (LVC) is the voltaghe level at which the charger disconncts the load from the battery. It is when the battery stops pwoering your fans, refrigerators and other loads in the house. the function of the cut-off voltage is to prevent the battery from enetering the deep discharge stage.
Soft Start
(Gentle to your appliances)
A great beginning makes way for a great journey. Fusion eco knows this very well.
Unlike traditional inverters that allow a sudden inrush of current which can be harmful to your appliances, Fusion eco goes for a cushioned start-up.
It gradually increases the voltage to let your appliances ease-in. This prevents electrical and mechanical shocks to the sensitive and costly appliances in your house.
Generator Compatible
Many times when the local grid fails, you need to depend on your Domestic Power Generators.
Ordinary inverters are incompatible with such ACs due to their high fluctuations. But Fusion eco can normalize and adapt to such fluctuations, making it perfect to pair up with Domestic Generators because our UPS has a frequency bypass range of 42Hz – 55Hz.
Overload & Short circuit Feature
We have given a special overload feature in which when the ups once get overloaded will give 8 times retry before it shuts down. This feature is very important for the customer as when the costumer put extra load which cannot be supported by the ups then it switch off immediately and keep giving warning.
Then customer has to reduce the load and go to the ups and reset the front switch which is very uncomfortable for the costumer because at times the whole house gets into darkness and for the costumer to switch off the load and reaches to the ups is tough as it laying in one corner of the house or office.
So we have given a special feature in our ups, in case of overload our ups gives you 8 times switching on and off load, in that timing costumer can reduce the load and there is no sudden darkness in the house/office.
Just like overload retries our UPS has a feature of short circuit retries as well. In this feature whenever there is a short circuit our UPS will shut down automatically and start again. In this process our UPS will check whether the condition of short circuit has been eliminated or not if the short circuit has been eliminated the UPS will start working normally and if condition of short circuit continues then our UPS will retry 4 times before permanently shut down. In order to make it operational again, reset the front switch of UPS.
Isolation Transformer
Our UPS have Built-in Isolation Transformer. Isolation also referred to as galvanic isolation, implies that no direct path exists for the current
to flow from the source to the load. An isolation transformer provides isolation between the electrical devices and the source powering these devices. In other words, with an isolation transformer, the output power circuit is electrically and physically isolated from the input power circuit. As a result, the isolation transformer provides safety to the users and the appliances.
Bi-Directional Technology
Su-vastika’s UPS works on the Revolutionary Bi-directional technology. A bi-directional technology is a technology that allows for two-way charging due to its ability of two-way conversion—from AC to DC and from DC to AC.
A bi-directional technology uses the same PWM (Pulse Width Modulation) based, MOSFET (metal–oxide–semiconductor field-effect transistor) circuit to charge and discharge the battery.
LCD Display Message
So now you know why we say Falcon Plus is the smartest thing we’ve ever made. Well, it’s just because when we set out to make a product, we don’t aim for beating our competition, we instead aim to push humanity forward.
Technical Specification
*SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT ANY PRIOR NOTICE
MODEL(FUSION ECO) |
2800A |
BATTERY VOLTAGE |
24V |
TECHNOLOGY |
LATEST BI-DIRECTIONAL TECHNOLOGY |
MAINS MODE | |
INPUT VOLTAGE RANGE (WUPS MODE) |
85V-290V |
INPUT VOLTAGE RANGE (UPS MODE) |
185V-265V |
OUTPUT VOLTAGE |
SAME AS INPUT |
CHARGING CURRENT |
15A, 20A (USER SELECTABLE) |
FREQUENCY BYPASS RANGE |
42Hz- 55Hz |
CHANGE OVER TIME | |
UPS MODE |
≤ 8 ms |
WUPS MODE |
≤ 20 ms |
BATTERY MODE | |
OUTPUT WAVEFORM |
PURE SINE WAVE |
OUTPUT FREQUENCY |
50.0 ± 0.1Hz |
TOTAL HARMONIC DISTORTION (THD) |
<3% |
PROTECTIONS | |
MAINS MODE: | |
OVERLOAD/SHORT CIRCUIT |
MAINS MCB WILL TRIP |
BATTERY OVERCHARGE |
BATTERY HIGH CUT |
BATTERY MODE: | |
OVERLOAD PROTECTION |
YES WITH 8 TIMES AUTO RESET |
SHORT CIRCUIT PROTECTION |
YES WITH 4 TIMES AUTO RESET |
OVER TEMPERATURE PROTECTION |
YES HIGH TEMPERATURE SHUTDOWN |
AUTOMATIC TEMPERATURE COMPENSATION (ATC) |
-10°C to 60°C |
OPERATING TEMPERATURE |
-10°C to 45°C |