We know how important power is for living in today’s world and how to deliver it just right. Su-vastika’s PURE SINE WAVE UPS 850/12V LED provides power backup to your home, office, or commercial establishment without interruption or blackout, keeping you always comfortable and connected. The Su-vastika’s Uninterrupted Power Supply, called UPS range, is available in various configurations to meet power backup needs according to your load requirement. https://en.wikipedia.org/wiki/Uninterruptible_power_supply
Every UPS goes through strict quality control, i.e., Automated Testing Zig & comes with robust after-sales support and warranty (one-of-a-kind replacement warranty of 24 Months). Su-vastika’s UPS allows us to live an unlimited energy lifestyle.https://suvastika.com/what-is-pure-sinewave-inverter-ups/#:~:text=A%20pure%20sine%20wave%20inverter%20is%20an%20electronic,wave%20inverters%2C%20but%20it%20offers%20several%20benefits%2C%20including%3A
Trolley and battery are only for illustrative purpose. Not sold by Su-vastika
Various Load Combinations
POWERFUL FEATURES THAT COME WITH PURE SINE WAVE UPS 850/12V LED
Pure Sine Wave Technology
Many inverters still provide a square wave output, which is unhealthy for your appliances and creates a humming noise in the fans and appliances.
Su-vastika’s PURE SINE WAVE UPS 850/12V LED is designed to give your appliances a smooth, pure sine-wave power output that is better than the grid power we get.
Smart AVR (Automatic Voltage Regulation)
In developing countries, frequent voltage and frequency fluctuations in households are common occurrences. The moment the voltage supply goes below a certain level, we observe the speed of fans going slow or the water cooler fan’s speed dropping, indicating that the voltage is lower than the standard voltage. We have provided two types of settings in our model.
- Wide UPS Mode
- UPS Mode
PURE SINE WAVE UPS 850/12V LED has the Smart Automatic Voltage Regulation (AVR) feature, or when your mains supply voltage fluctuates (rises or drops beyond the Safe Voltage range), Our UPS seamlessly switches to the battery power, ensuring a safe power supply to all your appliances.
Fast Switching- Intelligently changing between mains and backup
Traditional inverters/UPS have higher switching times. This means your appliances will reset during the changeover between mains to back up, but Su-vastika’s UPS is blazingly fast. It automatically detects a power cut or voltage fluctuation and switches to its backup mode in milliseconds. So you and your appliances won’t even know there was a power cut. This means your computer, TVs, Satellite receivers, Wi-Fi, and other critical equipment can run uninterrupted without resetting.
Bi-Directional Technology
Su-vastika’s PURE SINE WAVE UPS 850/12V LED works on the Revolutionary Bi-directional technology. Bi-directional technology allows for two-way charging due to its ability to convert from AC to DC and from DC to AC. A bi-directional technology uses the same PWM (Pulse Width Modulation) based MOSFET (metal–oxide semiconductor field-effect transistor) circuit to charge and discharge the battery.
Powerful charging from 110V–280V for fast battery charging
In Low-voltage areas, people generally use voltage stabilisers to charge the battery as the Inverter/UPS cannot charge the battery when the voltage is low. In our UPS, we have designed the charger in such a way that it has a built-in Voltage stabiliser for charging the Inverter/UPS Battery
from 110Volts to 280 volts at a constant charging current, an essential feature where the Low and high voltage problems are faced> so the battery charging time doesn’t increase with the Low or high voltage fluctuations.
Battery Selection Switch (Compatible with Tubular/SMF)
Su-vastika Pure Sinewave UPS has a Battery Selection switch at the back panel through which the user can select the type of battery viz Tubular/ SMF as per the battery type one is installing.
Innovative Three Stage Charging
1. BULK STAGE:
The charging current is fed to the battery bank. The battery voltage level will be increased as the battery gets charged. Battery Charges in this stage until its voltage level reaches bulk setting level.
2. ABSORPTION STAGE:
In this stage, battery voltage is held at a bulk setting level for one hour. The charging current reduces as the battery is charged to its capacity.
3. FLOAT STAGE:
In this stage, battery voltage is held at float setting level, and the charging current is further reduced. Full current can be provided to loads connected to the battery during the float stage from the grid.
TRANSITION FROM FLOAT TO BULK STAGE
When the battery voltage drops below the float setting for a cumulative period of one hour, a new bulk cycle will be triggered. This typically occurs each night. This three-stage charging process results in faster and safer recharging of the battery bank without getting it over.https://suvastika.com/how-to-charge-tubular-battery-in-inverter-ups/
Built in Isolation Transformer
Our UPS have a Built-in Isolation Transformer. Isolation, also called galvanic isolation, implies that no direct path exists for the current to flow from the source to the load. An isolation transformer provides isolation between the electrical devices and the source powering these devices. In other words, the output power circuit is electrically and physically isolated from the input power circuit with an isolation transformer. As a result, the isolation transformer provides safety to the users and the appliances by preventing the current from passing through the body of the product, making it very safe.
Advanced Protection with MCB
A safe voltage range is important to keep appliances safe during high voltage spikes. The Short circuits are very common. Therefore, every household is equipped with an MCB or main fuse. However, these can be slow and inefficient at protecting your appliances from damage. We know how much you love your appliances. Therefore, we have designed Our UPS to add a smart layer of protection to them. It has an inbuilt Special MCB, which trips and protects all your appliances before the traditional MCB can respond.
Overload & Short circuit Feature
The Overload and Short Circuit at the Inverter mode is an important feature to understand. Our UPS has full control in the situation of Overload and short circuit, and one can do times Overload and Short circuit, nothing will happen to the UPS. At smaller UPS, one can install an Air conditioner, but our UPS is fully safe for whatever heavy load you try to run through this UPS as the Overload and Short circuit protection save our UPS.
Soft Start (Gentle to your appliances)
A great beginning makes way for a great journey. Our UPS knows this very well. Unlike traditional inverters that allow a sudden inrush of current, which can harm your appliances, Su-vastika’s UPS goes for a cushioned start-up. It gradually increases the voltage to let your appliances ease in. This prevents electrical and mechanical shocks to your house’s sensitive and costly appliances.
Safe Discharge
With prolonged usage, a battery’s life gets reduced. This happens to every battery after multiple charge-discharge cycles, even inverter batteries. Nerds call it battery fatigue. Our UPS knows how to beat this problem, too. When the battery is being used to power your home and is about to get empty (but not fully empty), Pure Sine Wave UPS places a reserve. This means it doesn’t let the battery get fully or deeply discharged, hence extending the life of the battery.
Compatible with Local Generator
When the local grid fails, you must depend on your Domestic Power Generators. Ordinary inverters are incompatible with such ACs due to their high fluctuations. But Su-vastika’s UPS can normalize and adapt to such fluctuations, making it perfect to pair up with Domestic Generators because our UPS has a frequency bypass range of 42Hz – 55Hz.
Su-vastika Economic UPS is now available in a wide range of Selections
700VA/ 12 – 2000VA / 24V