Home & Commercial UPS Pure Sine Wave LCD
The meaning of UPS is Unintteruptible Power Supply (UPS).
We know how important power is for living in today’s world and how to deliver it just right. Su-vastika’s PURE SINE WAVE UPS WITH ATC LCD provides power backup to your home, office, or commercial establishment without interruption or blackout, keeping you always comfortable and connected. The Su-vastika’s UPS range is available in various power configurations to meet power backup needs according to your load requirement. Every UPS goes through strict quality control, i.e., Automatic Testing Machines for Inverter/UPS & comes with robust after-sales support and warranty. Su-vastika’s UPS allows us to live an unlimited energy lifestyle.
Su-vastika’s Certifications
- CE Certified
- ISO 9001
- IEC Certificate
- BIS Certified Products
- Govt Recognised Star Export House Certificate
- Electrical Contractor License
- Start-up India Certificate
- MSME Certificate
Remote Monitoring
What Is ATC?
Automatic Temperature Control/ATC is a unique sensor added to Su-vastika Pure sine wave UPS. ATC allows our UPS to switch between 6-stage charging based on the outside temperature.
Why Is ATC Important?
A battery gets adversely affected because of the ambient temperature. ATC allows choosing the right charging stage whenever there is a temperature fluctuation. This is extremely important in places where temperature varies throughout the year. So, when the temperature increases, a generic battery might stop charging, but the Su-vastika UPS series with ATC will keep on charging. With this feature, on average, the battery’s lifespan is increased by up to 1 year.
Adaptive Performance Using ATC
Su-vastika UPS with ATC is designed for rough weather conditions. It has an ambient sensor placed right upon it. With advanced Automatic Temperature Compensation (ATC) built right into the microprocessor, Su-vastika UPS senses the temperature around it and then makes intelligent adjustments. For example, the temperature is high in summer or hotter regions, so the battery is charged to a lower voltage for the same power backup performance. This saves you some extra bucks while ensuring the battery doesn’t overheat, loose water, or get damaged.
Similarly, in winter or colder places, the temperature is lower, so the battery is charged to a higher boost voltage to ensure you get the required or expected amount of power backup. This makes our UPS with ATC a perfect choice for any climate; from the extremes of Northern America and Europe to the beating heat in Middle-East and South-East Asia, we are ready for a rough world.
50/60Hz Automatic Switching Technology
An inverter, along with the charger, is a device that converts direct current (DC) to alternating current (AC). Also, the Charger part charges the battery from the primary Source or main Power having 50 or 60 Hz Frequency. The frequency of AC power varies depending on the country or region. For example, the frequency in North America is 60Hz, while Europe’s is 50Hz.
There are three significant Voltages and Frequency standards being followed in the world 220V/50Hz, 220/60Hz, and 110/60Hz. Most of companies design separate Inverters/UPS on either 220/50Hz or 220V/60Hz, or 110/60Hz as they have different frequencies in those countries. A 50/60Hz compatible inverter can operate on 50Hz- and 60Hz power sources.
We at Su-vastika have universal compatibility as far as 50 or 60 Hz frequency is concerned. Please check our models, where these products work on both frequencies automatically. When they sense the frequency in the mains mode, they bypass the same frequency, and when the Power goes automatically, they begin providing Power on the same frequency.
This feature is critical as it helps us send the same model to a few countries with the Power of 220/60 Hz or the nations with an emphasis of 220V/50 hz. The product is standard and can be installed in any country.
Lithium Battery Compatible
Su-vastika introduces advanced inverter/UPS models that are compatible with Lithium, providing enhanced performance and efficiency. These inverters are specifically designed to work seamlessly with lithium-ion battery systems, offering reliable and sustainable power solutions for various applications. We have provided the settings in our UPS and user can select Lithium battery. Accordingly, the user can set the grid charging current from the settings as per the size of the Lithium battery chosen. We have designed the LifePO4 chemistry in our UPs and not the Lithium-ion as the Lithium-ion and Lithium LifePO4 technologies are very different from each other. In the Lithium LifePO4, you will get a better life, faster charging and better safety as well.
Fast Switching- Intelligently Changing Between Mains And Backup
Traditional inverters/UPS have higher switching times. This means your appliances will reset during the changeover between mains to backup, but Su-vastika’s UPS is blazingly fast. It automatically detects a power cut or voltage fluctuation and switches to its backup mode in milliseconds. So you and your appliances won’t even know there was a power cut. This means your computer, TVs, Satellite receivers, Wi-Fi, and other critical equipment can run uninterrupted without resetting.
Pure Sine Wave Technology
Many inverters still provide a square wave output, which is unhealthy for your appliances and creates humming noise in the fans and appliances.
Su-vastika’s Pure Sinewave UPS is designed to provide your appliances with a smooth, Pure Sine-wave power output better than the Grid power we get.
Bi-directional Technology
Su-vastika’s PURE SINE WAVE UPS 2300/24V LED works on the Revolutionary Bi-directional technology. A bi-directional technology is a technology that allows for two-way charging due to its ability of two-way conversion—from AC to DC and from DC to AC. A bi-directional technology uses the same PWM (Pulse Width Modulation) based MOSFET (metal–oxide–semiconductor field-effect transistor) circuit to charge and discharge the battery.
Inbuilt Isolation Transformer
Our UPS have Built-in Isolation Transformer. Isolation also referred to as galvanic isolation, implies that no direct path exists for the current to flow from the source to the load. An isolation transformer provides isolation between the electrical devices and the source powering these devices. In other words, with an isolation transformer, the output power circuit is electrically and physically isolated from the input power circuit. As a result, the isolation transformer provides safety to the users and the appliances by preventing the current to pass to the body of the product, hence making it very safe.
Automatic Bypass
Automatic Bypass is the ability of UPS to transfer the load to the mains electricity supply when there’s an internal fault or failure.
When there is a technical error in the UPS, it might not be able to switch the load back to the main supply automatically.
Su-vastika UPS with ATC has a feature of an ‘Automatic bypass system’ which bypasses the Mains supply even when the UPS is faulty.
LCD Display
LCD display is the display function of a UPS that shows key metrics to users to help them make an informed decision.
Su-vastika Premium UPS with ATC comes with a built-in LCD display that shows messages, including customized messages so that the user and service personnel can know what is happening inside the UPS and take the right action if required.
Various Type Of Settings In The Ups With ATC
There are lot of settings in this UPS the first.
1st is Wide UPS and UPS mode
2nd is Battery type selection
3rd is Grid Charging Current
4th is Battery Reserve Mode
5th is Buzzer on and off control
Last one is Alert Sound on the mobile phone.
Safe Voltage Range
A safe voltage range is important to keep appliances safe during high voltage variations and spike and surges. The problem is that there could be times when due to a high voltage, the appliances connected with the home wiring getting damaged but if those appliances are connected through our UPS then they are safe as this UPS has the sensing circuit in the microprocessor which keep sensing the voltage and frequency of the Mains power and the moment the High Voltage or Low Voltage is detected it shifts to UPS/battery mode to save the appliances.
With Su-vastika Pure sine wave UPS with ATC, your UPS has ability to maintain Safe Voltage ranges, hence the appliances will remain safe from high voltage spikes as it rapidly switches from the mains to the battery.
Ability To Charge At Low Voltage
Typically, low voltage areas specially developing countries or war torn countries like Syria, Afghanistan, Iraq, Yemen, Sudan, Somalia, Ethopia, Pakistan, Cameroon and Nigeria etc. experience high voltage fluctuations because of grid is not stable and these countries’ people face lot of appliances getting damaged. Due to these voltage fluctuations, battery charging in the UPS is a tough thing to happen. To avoid this problem, people use Voltage stabilizer along with the Inverter/UPS to charge the battery.
Su-vastika Pure sine wave UPS with ATC is equipped with Advanced Microprocessor which take care of this issue and charge the battery at as low voltage as 90 Volts without any Voltage stabiliser and can charge properly at higher voltage like 280Volts which is a major feature of our UPS with ATC model.
Advanced Protection With MCB
A safe voltage range is important to keep appliances safe during high voltage spikes. Short circuits are very common. Therefore every household is equipped with an MCB or main fuse. However, these can be slow and inefficient at protecting your appliances from damage. We know how much you love your appliances. Therefore, we have designed Our PURE SINE WAVE UPS 2300/24V LED to give them a smart layer of protection. It has an inbuilt Special MCB, which trips and protects all your appliances before the traditional MCB can respond.
Safe By Pass Mode For Voltage And Frequency Coming From The Mains Power
We have provided the feature of By pass Load, which is higher than the normal capacity of UPS. This feature helps the user to keep the provision of higher load so that one can get the UPS connected to the whole house or office and can choose which load to run when the power is not available.
This feature allow the user to install the UPS on the whole house load and all those appliances connected with this UPS get the protection of High and Low Voltage protection along with the Frequency variation protection as well, which cant be provided by the MCBs installed in the home or offices.
Load Percentage
User can see percentage of load running on LCD display and can Monitor & Optimise Inverter/UPS Health.
Stay informed about the current load on your UPS without needing to approach it physically. Detect overloads and make informed decisions to reduce the load for optimal performance. Identify the wattage of individual devices and manage their power consumption effectively. Ensure the health of your UPS by maintaining a balanced load percentage and upgrade if necessary.
Soft Start (Gentle To Your Appliances)
A great beginning makes way for a great journey. Our UPS knows this very well. Unlike traditional inverters that allow a sudden inrush of current which can be harmful to your appliances, Su-vastika’s UPS goes for a cushioned start-up. It gradually increases the voltage to let your appliances ease-in. This prevents electrical and mechanical shocks to the sensitive and costly appliances in your house.
Safe Discharge
With prolonged usage, a battery’s life gets reduced. This is what happens to every battery after multiple charge-discharge cycles, even inverter batteries. Nerds call it battery fatigue. Our UPS knows how to beat this problem too. When the battery is being used to power your home and is about to get empty (but not fully empty), Pure Sine Wave UPS places a reserve. This means it doesn’t let the battery get fully or deeply discharged, hence extending the life of the battery.
Battery Size Selection
Every battery is built to accept a certain maximum allowed charging speed. A Tubular Lead-Acid battery needs a minimum of 10 hours, a Sealed Maintenance Free (SMF) battery requires 6-8 hours, while a Lithium-lon battery requires 2-4 hours to get fully charged healthily. Charging the batteries faster than these healthy limits reduces the battery’s life and increases maintenance costs and hassles. That’s why Pure Sinewave UPS with ATC is built with the Right Charger that charges batteries at optimum speed.
Battery Selection Switch is an innovative feature of Pure Sinewave UPS with ATC that enables you to select the battery charging current for choosing a small to a big battery. So, in other words, if you need a short backup time, you can select a small battery; if you need a long backup, you can choose a bigger one. We have two ways of selecting battery charging one is with the DIP switches, and the other is a Mobile app in which you can choose the charging current in the settings.
Overload & Short-circuit Protection
We have given a special overload feature in which when the ups once get overloaded will give 8 times retry before it shuts down. This feature is very important for the customer as when the costumer put extra load which cannot be supported by the ups then it switch off immediately and keep giving warning. Then customer has to reduce the load and go to the ups and reset the front switch which is very uncomfortable for the costumer because at times the whole house gets into darkness and for the costumer to switch off the load and reaches to the ups is tough as it laying in one corner of the house or office. So we have given a special feature in our ups, in case of overload our ups gives you 8 times switching on and off load, in that timing costumer can reduce the load and there is no sudden darkness in the house/office. Just like overload retries our UPS has a feature of short circuit retries as well. In this feature whenever there is a short circuit our UPS will shut down automatically and start again. In this process our UPS will check whether the condition of short circuit has been eliminated or not if the short circuit has been eliminated the UPS will start working normally and if condition of short circuit continues then our UPS will retry 4 times before permanently shut down. In order to make it operational again, one needs to reset the front switch of UPS.
Low Battery Warning
Low Battery Warning in Su-vastika UPS helps to Protect Batteries and Ensure Power Reliability.
Learn about the importance of low battery warnings and how they safeguard batteries from damage while ensuring uninterrupted power supply. Explore the difference between low-voltage battery cut offs for lead acid and lithium batteries, as well as how the Su-vastika Inverter/UPS employs this safety feature to provide timely alerts and prevent deep discharge. Discover the benefits of implementing low-voltage battery cut offs in critical applications to maximize battery life and maintain reliable backup power systems.
Compatible With Local Generator
Many times when the local grid fails, you need to depend on your Domestic Power Generators. Ordinary inverters are incompatible with such ACs due to their high fluctuations. But Su-vastika’s UPS can normalize and adapt to such fluctuations, making it perfect to pair up with Domestic Generators because our UPS has a frequency bypass range of 42Hz – 55Hz.
Advantages Of Lithium Battery VS Lead Acid Batteries
Lithium Battery ESS Is Cheaper Than Traditional Inverters With Lead Acid Batteries
Having built SMF battery and Lithium inbuilt BESS, has a price difference of 50%, but the life is five times the battery life of the same capacity.
The life of the battery in the Lithium is more than 12 years for home and office backup purposes as the cycle life pf Lithium LifePO4 battery is 3000 cycles compared to a Lead Acid battery which gives a maximum of 400 cycles, that too if you do the proper maintenance by filling the battery with water topping in time. Lithium has 6 to 8 times the life cycle of a tubular battery, which will have a life of 12 years, in which period you will be changing at least four Lead acid batteries. So the cost of 5 Lead acid batteries compared to one Lithium battery is too low.
If we take the cost of a 70Ah Lithium battery compared to a 150Ah tubular battery, the price is almost 30 to 40% extra initially, but the life is a minimum of 4 times where the Lithium wins in the pricing part.
Comparison Of Inbuilt Battery ESS VS Traditional UPS/ Inverter With Lead Acid Batteries
Parameter | Inbuilt Lithium Battery ESS | Traditional Inverter With Lead Acid Battery |
---|---|---|
Efficiency | ESS runs with powerful Inbuilt Lithium Ion (LiFePO4) Battery, which has 3 Time higher efficiency than traditional batteries resulting higher back up and output | Traditional Inverters battery have lower efficiency as compared to Lithium-Ion battery |
All-in-one Backup | ESS system is all you need, whether you want to use it for IT/any other sensitive loads and Lighting/home appliances load. It can handle every appliance perfectly without having to buy a separate unit for every backup need in the home. | Users need to buy different Inverter systems for IT equipment and lighting/home appliances load, which means double the cost. |
Looks | ESS looks stunning and modern and perfectly blends with any environment. Its beautiful design is difficult to match with any traditional inverter on the market. | Nothing can be as bland as a traditional Inverter. These inverters look really clunky and are so big that they are bound to look out of place no matter where you keep them. |
Size and Space | The sleek design of ESS ensures that less space is needed. No trolley is needed to stack the battery as is inbuilt inside the ESS. With sleek and elegant design, it can be kept anywhere in the house like drawing rooms | The tubular battery is very heavy and bulky, making it mandatory to change it every 2-3 years. This is quite difficult and cumbersome as it will need two people to hoist it, and if you have stairs, it will be 5difficult to get the 70 KG batteries inside for installation or repair. Additional trolley is needed to store the battery. |
Portable | ESS weighs just 25% of a typical lead-acid based traditional Inverter, hence, it can be used for multipurpose. If one is going out for a short trip, they can take the ESS with them and use its power to give back up to laptop, music systems, mobile charging, camping and all. It can run for up to 20 hours if fully charged. | Traditional Inverter and Lead acid batteries are very heavy and are not portable |
Compact, Safe, Reliable, Ease of Handling | The ESS set-up is clean and safe for everyone in the house. Contrary to the traditional inverter, there are no hanging wires and terminals with ESS which can be hazardous to the safety of children and pets at home | In most of the cases, when the user or dealer refills the battery water than after the battery is charged the water comes out and creates havoc as the water contains acid and the floor is damaged permanently. Hanging wires and terminals can be dangerous to the safety of children and pets at home |
No Maintenance/ Refilling Of Battery Required | ESS doesn’t require refilling as it has a rechargeable LiFePO4 lithium-ion battery. | Tubular batteries with traditional Inverters need refilling of water periodically and it must be done with distilled water each time. Since most consumers and dealers are unaware of this requirement, they frequently use alternative types of water, further shortening the battery’s lifespan. |
Spilling of Harmful Battery Water | ESS is based on LiFePO4 battery, which doesn’t require any harmful liquid refilling. It is easy to manage and replace, making it completely safe for kids and pets | Refilling of battery water can cause water spillage. This water contains acid, often damaging the floor. It is also hazardous for kids and pets, making it a non-family-friendly option. |
Charging Time | ESS gets charged in 3 hours as the Lithium Ion battery charges faster. It can be used 4-5 times a day. Ideal for areas with frequent power cuts, such as India. | Lead acid batteries, especially tubular batteries, take a minimum of 10-12 hours to charge. In winter, acid and water expand and contract, so they can be used only once during the day since the charging takes more time. |
Low Running Cost/ Low Consumption of Electricity | Since charging time of ESS is 1/4th that of a lead acid battery, it uses less electricity than traditional inverter by at least 30%.Being a smart inverter, ESS automatically chooses the best AC power source for battery charging and supporting load during the day, which lowers the power consumption for battery charging and lowers the cost of electricity. | Lead acid batteries, especially Tubular batteries, continue to charge even after being fully charged, which drives up the cost of electricity.Therefore, even when there are no power outages, traditional inverter uses at least 1 unit of electricity. The bigger size of Inverter/UPS even takes 3 to 5 units per day. |
Life of The ESS | ESS has long life of 7 to 10 years as Lithium ion batteries are required to change in 7 to 10 years. It has an extremely long lifespan (3000 cycles) due to a discharge rate of just 20%. | Due to the Lead Acid battery’s dependence on constant water filling, which the consumer cannot monitor, it has a much shorter lifespan than Lithium ion battery and needs to be replaced in every 2-3 years. |
Easy Installation | The Installation of ESS works on Plug and Play model which is completely hassle free for every household. | Need and engineer/expert for installation, connections and settings for Traditional Inverter with Lead acid/SMF batteries |
No Manual Settings | ESS requires no manual intervention, even when it comes to settings, making it hassle-free for everyday users. | Traditional inverters settings need to be set as per individual requirements, which means you are always in need of an expert. |
Switching Technique | ESS has a fast switching technology which is required by the IT equipment and the heavy machinery which gives them uninterrupted power to them in case if power cuts or power failures. Su-vastika uses advanced Static switches in its ESS that reduce switching time to just 2ms to 5ms, which is fast enough to prevent a computer and most sensitive equipment from resetting. | Traditional Inverter has long switching time which interrupts the working of equipment till battery mode is active |
Back Up Time | ESS’s unique Lithium Ion batteries takes significantly lesser time to charge. In other words, in situations where there are frequent power cuts, ESS will provide greater back up hours simply because of its ability to charge faster. | Lead acid based Traditional Inverter takes greater time to charge and still provides lesser back up time throughout the day. |
High Power Quality | When a load is connected, ESS produces pure sine waves with lower THD than traditional inverter. Due to the extremely low THD variance, ESS generates Pure sinewave output and pure power is continually maintained for IT loads like computers, printers, routers, etc | Traditional Inverters are available in Square wave or Sinewave. When a load is connected to an inverter, the THD always changes, which causes harmonics and is bad for sensitive loads, especially IT loads. |
Pollution and Health Hazards | Fitted with Lithium-ion batteries makes ESS more environmentally friendly as it can be recycled economically. There are no harmful fumes to worry about. The set-up is clean and safe for everyone in the house. | Traditional inverters emit harmful gases that pollute indoor air. It also ends up in landfills which causes land pollution. High-intensity fumes of lead can cause long-term diseases. Lead vapours from the lead acid battery are released in high concentrations when it is charged and discharged, making them extremely dangerous for children and adults. These lead vapours can cause long-term illnesses in people because they immediately enter the bloodstream and raise the level of lead there. |
Self Discharge While Charging | ESS has the new technology in charging. Lithium-Ion batteries are charged faster and once charged 100%, it does not need charging to maintain it to 100% as its self-discharge is very low as compared to Lead Acid battery. | The lead acid batteries specially Tubular batteries never stop charging even when they are charged so the trickle charging keep happening which increases the electricity bill and affect the battery life |
Full Capacity at Different Discharge Levels | The Lithium Ion battery enables ESS to run any load to its full capacity of 100% unlike | Lead-acid based Traditional inverters which if discharged at the rate of 50%, will give only 50% of its rated capacity. |
Self-Diagnostics | ESS provides a self-discharge measurement and a self-diagnosis feature which means no manual intervention is required. | No self-diagnosis mechanism, which means technicians might need to conduct multiple tests to even diagnose small errors. |
Bluetooth/Wifi (Optional) | ESS comes with optional Bluetooth/WiFi connectivity which allows remote monitoring & control. Using the dedicated app, you can now easily check your ESS status and monitor and control it even when you are away. One can also do Remote diagnosis of system by fetching the data through Bluetooth/Wi-Fi | Traditional Inverter has no Bluetooth or WIFI capability, which is really inconvenient for modern users. |
GPS | ESS has an optional GPS feature that makes it an Anti-theft product that is immune to theft, as you can find its location in real-time. | Traditional Inverter can be easily stolen when you’re away from home on vacation, or when you’ve left your home unprotected. There is no option to track it without GPS |
Remote Diagnosis | One can diagnose ESS system even remotely if you have your smartphone with you. With it’s Wi-fi connectivity feature and dedicated mobile app, you can monitor, diagnose and generate reports without having to be physically present. | There is no support for remote diagnosis, meaning whenever there is a problem with your Traditional Inverter, you have to be physically present to do any kind of diagnosis. |
Digital Warranty
Su-vastika brings in a Digital warranty for Inverters, a remarkable, revolutionary, and mindful innovation. Su-vastika’s Digital warranty is linked with the microprocessor in the PCB Mains card of complete range of Inverters, UPS, Online UPS, Solar Hybrid PCU, ERD, ESS.
The warranty shall start only when Inverter is connected to Battery, and when the Battery is disconnected from Inverter, the warranty stops. This addresses one of the common concerns with traditional warranty models. With this approach, the warranty remains valid as long as the Inverter is actively in use, regardless of the reason for its temporary disconnection, such as the Inverter or Battery not working or the owner being away on vacation.
The warranty can be accessed very easily by connecting your Inverter through Su-vastika Bluetooth/ WIFI app or via data transfer wire to computer.
The calculation of the Digital warranty provided by Su-vastika is based on a descending order system, represented in Moths, Days, Hours, Minutes, and Seconds.
Quick Links
Latest News
Head Office
Shed No 66D, Phase-6,
Udyog Vihar, Gurugram,
Haryana-122004
Email : info@suvastika.com
Toll-free : 1800-202-4423
Sales : +91 9711 774744